{"id":5418,"date":"2026-08-07T06:55:33","date_gmt":"2026-08-06T21:55:33","guid":{"rendered":"https:\/\/www.aem.imr.tohoku.ac.jp\/?p=5418"},"modified":"2026-08-07T06:55:33","modified_gmt":"2026-08-06T21:55:33","slug":"jem-2100plus%ef%bc%9a%e8%a9%a6%e6%96%99%e6%b1%9a%e6%9f%93%e9%98%b2%e6%ad%a2%e8%a3%85%e7%bd%ae","status":"publish","type":"post","link":"https:\/\/www.aem.imr.tohoku.ac.jp\/en\/jem-2100plus%ef%bc%9a%e8%a9%a6%e6%96%99%e6%b1%9a%e6%9f%93%e9%98%b2%e6%ad%a2%e8%a3%85%e7%bd%ae\/","title":{"rendered":"JEM-2100Plus: Sample Contamination Prevention Device"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\"><em>Note: This page was translated by AI from the Japanese original. In case of any discrepancy, the Japanese version shall prevail.<\/em><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><em>Original post date (Japanese version): June 22, 2024<\/em><\/p>\n\n\n\n<p class=\"has-background wp-block-paragraph\">&#x1f4a1; Safety<\/p>\n\n\n<p class=\"has-background wp-block-paragraph\">&#x1f4a1; Please attend safety training regarding cryogens and high pressure gas at each department.<\/p>\n\n\n<p class=\"has-background wp-block-paragraph\">&#x1f4a1; Be especially careful when inserting and removing the sample holder when using the ACD.<\/p>\n\n\n<h3 class=\"wp-block-heading\">Refrigerant (LN2) supply<\/h3>\n\n\n<ol class=\"wp-block-list\">\n<li><span><strong>Preparation of LN2<\/strong><\/span>\n<ol class=\"wp-block-list\">\n<li>Ask the administrator to prepare an LN2 container at least one day before using the equipment.<\/li>\n<\/ol>\n<\/li>\n\n\n<li><span><strong>Advance confirmation<\/strong><\/span>\n<ol class=\"wp-block-list\">\n<li>Ensure that the column is in a sufficiently high vacuum before nitrogen injection\n<ol class=\"wp-block-list\">\n<li>SIP:5&#215;10-5Pa or less<\/li>\n<\/ol>\n<\/li>\n\n\n<li>There is no insulation defect in the ACD tank.\n<ol class=\"wp-block-list\">\n<li>The lamp does not light up when the installation confirmation switch is pressed. (Please note that the lamp is dimly lit even under normal conditions)<\/li>\n\n\n<li>If the heater is connected, remove it and check.<\/li>\n<\/ol>\n<\/li>\n<\/ol>\n<\/li>\n\n\n<li><span><strong>LN2 injection<\/strong><\/span>\n<ol class=\"wp-block-list\">\n<li>Health care\n<ol class=\"wp-block-list\">\n<li>Cover the observation window.<\/li>\n\n\n<li>Cover the equipment at the bottom of the ACD tank with bubble wrap.<\/li>\n<\/ol>\n<\/li>\n\n\n<li>Remove the cap from the ACD tank and insert the funnel.<\/li>\n\n\n<li>\u30b9\u30c6\u30f3\u30ec\u30b9\u88fd\u5bb9\u5668\u3092\u5e8a\u306b\u7f6e\u304f\u3002\n<p class=\"has-background wp-block-paragraph\">&#x1f4a1; Resin tables etc. may be damaged when injecting LN2.<\/p>\n<\/li>\n\n\n<li>Pour LN2 from the LN2 container into the stainless steel container. (about 1L)<\/li>\n\n\n<li>Pour LN2 from the stainless steel container into the ACD tank.<\/li>\n\n\n<li>Wait about 15 minutes (ACD tank will cool down)<\/li>\n\n\n<li>Add LN2 to ACD tank.<\/li>\n\n\n<li>Put on the cap.<\/li>\n<\/ol>\n<\/li>\n<\/ol>\n\n\n<p class=\"has-background wp-block-paragraph\">&#x1f4a1; <span><strong>Note<\/strong><\/span><\/p>\n\n\n<h3 class=\"wp-block-heading\">ACD heat<\/h3>\n\n\n<ol class=\"wp-block-list\">\n<li><span><strong>Stop accelerating voltage.<\/strong><\/span><\/li>\n\n\n<li><span><strong>Curing (protection from LN2)<\/strong><\/span>\n<ol class=\"wp-block-list\">\n<li><strong>Cover the observation window.<\/strong><\/li>\n\n\n<li>Cover the equipment at the bottom of the ACD tank with bubble wrap.<\/li>\n<\/ol>\n<\/li>\n\n\n<li><span><strong>Remove the ACD tank cap.<\/strong><\/span><\/li>\n\n\n<li><span><strong>\u30d2\u30fc\u30bf\u30fc\u3092\u51b7\u5a92\u6ce8\u5165\u53e3\u306b\u633f\u5165\u3059\u308b\u3002<\/strong><\/span>\n<ol class=\"wp-block-list\">\n<li>Connect the plug to the socket.<\/li>\n<\/ol>\n<\/li>\n\n\n<li><span><strong>Remove all restrictions<\/strong><\/span><\/li>\n\n\n<li><span><strong>ACD heat<\/strong><\/span>\n<ol class=\"wp-block-list\">\n<li>[TC : Control : Maintenance : ACD] ACD controller display<\/li>\n\n\n<li>[ACD Controller : ACD Heat : On] Start ACD heat<\/li>\n\n\n<li>The heater heats up, SIP stops, and the lens barrel becomes DP exhaust.<\/li>\n<\/ol>\n<\/li>\n\n\n<li><span><strong>automatically ends<\/strong><\/span>\n<ol class=\"wp-block-list\">\n<li>\u93e1\u7b52\u304cSIP\u6392\u6c17\u306b\u623b\u308b\u3002<\/li>\n<\/ol>\n<\/li>\n<\/ol>\n\n\n\n\n<p class=\"wp-block-paragraph\"><em>*This post was created by an AI agent.<\/em><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Note: This page was translated by AI from the Japanese original. In case of any discrepancy, the Japanese version shall prevail. Original post date (Japanese version): June 22, 2024 &#x1f4a1; Safety &#x1f4a1; Please attend safety training regarding cryogens and high pressure gas at each department. &#x1f4a1; Be especially careful when inserting and removing the sample <a href=\"https:\/\/www.aem.imr.tohoku.ac.jp\/en\/jem-2100plus%ef%bc%9a%e8%a9%a6%e6%96%99%e6%b1%9a%e6%9f%93%e9%98%b2%e6%ad%a2%e8%a3%85%e7%bd%ae\/\" class=\"more-link\">&#8230;<span class=\"screen-reader-text\">  JEM-2100Plus: Sample Contamination Prevention Device<\/span><\/a><\/p>\n","protected":false},"author":11,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_locale":"en_US","_original_post":"https:\/\/www.aem.imr.tohoku.ac.jp\/?p=3220","footnotes":"","jetpack_post_was_ever_published":false},"categories":[1],"tags":[],"class_list":["post-5418","post","type-post","status-publish","format-standard","hentry","category-uncategorized","en-US"],"jetpack_featured_media_url":"","_links":{"self":[{"href":"https:\/\/www.aem.imr.tohoku.ac.jp\/wp-json\/wp\/v2\/posts\/5418","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.aem.imr.tohoku.ac.jp\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.aem.imr.tohoku.ac.jp\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.aem.imr.tohoku.ac.jp\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/www.aem.imr.tohoku.ac.jp\/wp-json\/wp\/v2\/comments?post=5418"}],"version-history":[{"count":4,"href":"https:\/\/www.aem.imr.tohoku.ac.jp\/wp-json\/wp\/v2\/posts\/5418\/revisions"}],"predecessor-version":[{"id":5785,"href":"https:\/\/www.aem.imr.tohoku.ac.jp\/wp-json\/wp\/v2\/posts\/5418\/revisions\/5785"}],"wp:attachment":[{"href":"https:\/\/www.aem.imr.tohoku.ac.jp\/wp-json\/wp\/v2\/media?parent=5418"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.aem.imr.tohoku.ac.jp\/wp-json\/wp\/v2\/categories?post=5418"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.aem.imr.tohoku.ac.jp\/wp-json\/wp\/v2\/tags?post=5418"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}