{"id":5461,"date":"2026-08-07T06:55:35","date_gmt":"2026-08-06T21:55:35","guid":{"rendered":"https:\/\/www.aem.imr.tohoku.ac.jp\/?p=5461"},"modified":"2026-08-07T06:55:35","modified_gmt":"2026-08-06T21:55:35","slug":"jem-2100plus-%e8%a9%a6%e6%96%99%e7%a7%bb%e5%8b%95%e3%83%bb%e5%82%be%e6%96%9c","status":"publish","type":"post","link":"https:\/\/www.aem.imr.tohoku.ac.jp\/en\/jem-2100plus-%e8%a9%a6%e6%96%99%e7%a7%bb%e5%8b%95%e3%83%bb%e5%82%be%e6%96%9c\/","title":{"rendered":"JEM-2100plus: Specimen Stage Shift and Tilt"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\"><em>Note: This page was translated by AI from the Japanese original. In case of any discrepancy, the Japanese version shall prevail.<\/em><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><em>Original post date (Japanese version): June 22, 2024<\/em><\/p>\n\n\n\n<p class=\"has-background wp-block-paragraph\">&#x1f4a1; This page is a quick manual for the JEM-2100plus.\nThe contents are subject to change.\nPlease receive training in advance before actually using the equipment.<\/p>\n\n\n<p class=\"has-background wp-block-paragraph\">&#x1f4a1; Specimen Shift and Tilt<\/p>\n\n\n<h3 class=\"wp-block-heading\">Specimen Shift (Motor Driven) (X\/Y)<\/h3>\n\n\n<ol class=\"wp-block-list\">\n<li>[TC: TEM System Task Bar : Stage: X\/Y] Check specimen position<\/li>\n\n\n\n<li>[TC: TEM System Task Bar : Stage] Select movement speed\n<ol class=\"wp-block-list\">\n<li>Becomes faster in the order of &#x25b6;\u21d2&#x25b6;&#x25b6;\u21d2&#x25b6;&#x25b6;&#x25b6;<\/li>\n<\/ol>\n<\/li>\n\n\n\n<li>Move specimen with [TB: Trackball]\n<ol class=\"wp-block-list\">\n<li>Move independently for each axis with [TB : SHIFT +X\/-X\/+Y\/-Y] buttons<\/li>\n<\/ol>\n<\/li>\n\n\n\n<li>Coarse\/Fine (Movement Speed) Switching\n<ol class=\"wp-block-list\">\n<li>Switch with [TB: CRS]. When lit: Coarse<\/li>\n\n\n<li>[TB: CRS] is common to specimen shift (SHIFT-X\/Y\/Z:TILT-X\/Y) and specimen tilt<\/li>\n<\/ol>\n<\/li>\n\n\n\n<li>Initialize Specimen Position (X\/Y)\n<ol class=\"wp-block-list\">\n<li>[TEM Center: Upper menu] Control \u2192 STAGE<\/li>\n\n\n<li>Display Stage Controller<\/li>\n\n\n<li>Select [XY Neutral]<\/li>\n\n\n<li>Confirm with [TC: TEM System Task Ba : Stager]<\/li>\n<\/ol>\n<\/li>\n<\/ol>\n\n\n<h3 class=\"wp-block-heading\">Specimen Shift (Piezo Driven) (SFX\/SFY)<\/h3>\n\n\n<ol class=\"wp-block-list\">\n<li>[TC: TEM System Task Bar : Stage: SFX\/SFY] Check specimen position\n<ol class=\"wp-block-list\">\n<li>Relative position based on X\/Y. ~\u00b1100% (0.2um)<\/li>\n<\/ol>\n<\/li>\n\n\n\n<li>[TB: SUPER FINE] Piezo drive mode switching: On when lit<\/li>\n\n\n\n<li>[TC: TEM System Task Bar : Stage] Select movement speed\n<ol class=\"wp-block-list\">\n<li>Becomes faster in the order of &#x25b6;\u21d2&#x25b6;&#x25b6;\u21d2&#x25b6;&#x25b6;&#x25b6;<\/li>\n<\/ol>\n<\/li>\n\n\n\n<li>Move specimen with [TB: Trackball] or [TB : SHIFT +X\/-X\/+Y\/-Y]<\/li>\n\n\n\n<li>Coarse\/Fine (Movement Speed) Switching\n<ol class=\"wp-block-list\">\n<li>Switch with [TB: CRS]. When lit: Coarse<\/li>\n\n\n<li>[TB: CRS] is common to specimen shift (SHIFT-X\/Y\/Z:TILT-X\/Y) and specimen tilt<\/li>\n<\/ol>\n<\/li>\n\n\n\n<li>Initialize Specimen Position (SFX\/SFY)\n<ol class=\"wp-block-list\">\n<li>[TEM Center: Upper menu] Control \u2192 STAGE<\/li>\n\n\n<li>Display Stage Controller<\/li>\n\n\n<li>Select [SuperFIine Neutral]<\/li>\n\n\n<li>Confirm with [TC: TEM System Task Ba : Stager]<\/li>\n<\/ol>\n<\/li>\n<\/ol>\n\n\n<h3 class=\"wp-block-heading\">Specimen Tilt (TX\/TY)<\/h3>\n\n\n<ol class=\"wp-block-list\">\n<li>[TC: TEM System Task Bar : Stage: TX\/TY] Check specimen tilt<\/li>\n\n\n\n<li>[TC: TEM System Task Bar : Stage] Select movement speed\n<ol class=\"wp-block-list\">\n<li>Becomes faster in the order of &#x25b6;\u21d2&#x25b6;&#x25b6;\u21d2&#x25b6;&#x25b6;&#x25b6;<\/li>\n<\/ol>\n<\/li>\n\n\n\n<li>Tilt specimen with [SC : TILT +X\/-X\/+Y\/-Y] buttons<\/li>\n\n\n\n<li>Coarse\/Fine (Movement Speed) Switching\n<ol class=\"wp-block-list\">\n<li>Switch with [TB: CRS]. When lit: Coarse<\/li>\n\n\n<li>[TB: CRS] is common to specimen shift (SHIFT-X\/Y\/Z:TILT-X\/Y) and specimen tilt<\/li>\n<\/ol>\n<\/li>\n\n\n\n<li>Initialize Specimen Tilt (TX\/TY)\n<ol class=\"wp-block-list\">\n<li>[TEM Center: Upper menu] Control \u2192 STAGE<\/li>\n\n\n<li>Display Stage Controller<\/li>\n\n\n<li>Select [TX\/TY Neutral]\n<ol class=\"wp-block-list\">\n<li>Initialize for each axis<\/li>\n<\/ol>\n<\/li>\n\n\n<li>Confirm with [TC: TEM System Task Ba : Stager]<\/li>\n<\/ol>\n<\/li>\n<\/ol>\n\n\n<h3 class=\"wp-block-heading\">Specimen Shift (Z)<\/h3>\n\n\n<ol class=\"wp-block-list\">\n<li>[TC: TEM System Task Bar : Stage: Z] Check specimen height<\/li>\n\n\n\n<li>[TC: TEM System Task Bar : Stage] Select movement speed\n<ol class=\"wp-block-list\">\n<li>Becomes faster in the order of &#x25b6;\u21d2&#x25b6;&#x25b6;\u21d2&#x25b6;&#x25b6;&#x25b6;<\/li>\n<\/ol>\n<\/li>\n\n\n\n<li>Move specimen height with [SC :\u25b3Z\/\u25bdZ] buttons<\/li>\n\n\n\n<li>Coarse\/Fine (Movement Speed) Switching\n<ol class=\"wp-block-list\">\n<li>Switch with [TB: CRS]. When lit: Coarse<\/li>\n\n\n<li>[TB: CRS] is common to specimen shift (SHIFT-X\/Y\/Z:TILT-X\/Y) and specimen tilt<\/li>\n<\/ol>\n<\/li>\n\n\n\n<li>Initialize Specimen Tilt (Z)\n<ol class=\"wp-block-list\">\n<li>[TEM Center: Upper menu] Control \u2192 STAGE<\/li>\n\n\n<li>Display Stage Controller<\/li>\n\n\n<li>Select [Z Neutral]<\/li>\n\n\n<li>Confirm with [TC: TEM System Task Ba : Stager]<\/li>\n<\/ol>\n<\/li>\n<\/ol>\n\n\n<h3 class=\"wp-block-heading\">Stage Initialization<\/h3>\n\n\n<ol class=\"wp-block-list\">\n<li>[TEM Center: Upper menu] Control \u2192 STAGE<\/li>\n\n\n\n<li>Display Stage Controller<\/li>\n\n\n\n<li>Select [Stage Neutral]<\/li>\n\n\n\n<li>Confirm with [TC: TEM System Task Ba : Stager]<\/li>\n<\/ol>\n\n\n<h3 class=\"wp-block-heading\">Stage Position Memory\/Recall<\/h3>\n\n\n<ol class=\"wp-block-list\">\n<li>Specimen Position Memory\n<ol class=\"wp-block-list\">\n<li>[TEM Center: Upper menu] Control \u2192 Nanospace Map\n<ol class=\"wp-block-list\">\n<li>Display Nanospace Map<\/li>\n\n\n<li>Click [Memory] button<\/li>\n\n\n<li>The current holder position is memorized in the specimen position memory list.\n<ol class=\"wp-block-list\">\n<li>SFX\/SFY are not memorized<\/li>\n\n\n<li>Add a comment in the Memo field if necessary<\/li>\n<\/ol>\n<\/li>\n<\/ol>\n<\/li>\n<\/ol>\n<\/li>\n\n\n\n<li>Specimen Position Recall\n<ol class=\"wp-block-list\">\n<li>[TEM Center: Upper menu] Control \u2192 Nanospace Map\n<ol class=\"wp-block-list\">\n<li>Display Nanospace Map<\/li>\n\n\n<li>Select the specimen position from the <strong>specimen position memory list<\/strong><\/li>\n\n\n<li>Detailed information is displayed in the <strong>specimen position information display area<\/strong><\/li>\n\n\n<li>Click [Go] button<\/li>\n\n\n<li>The specimen position is recalled.\n<ol class=\"wp-block-list\">\n<li>Wait until the recall is complete.<\/li>\n\n\n<li>Do not operate [TB] or [SC] during recall.<\/li>\n<\/ol>\n<\/li>\n<\/ol>\n<\/li>\n<\/ol>\n<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\"><em>*This post was created by an AI agent.<\/em><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Note: This page was translated by AI from the Japanese original. In case of any discrepancy, the Japanese version shall prevail. Original post date (Japanese version): June 22, 2024 &#x1f4a1; This page is a quick manual for the JEM-2100plus. The contents are subject to change. Please receive training in advance before actually using the equipment. <a href=\"https:\/\/www.aem.imr.tohoku.ac.jp\/en\/jem-2100plus-%e8%a9%a6%e6%96%99%e7%a7%bb%e5%8b%95%e3%83%bb%e5%82%be%e6%96%9c\/\" class=\"more-link\">&#8230;<span class=\"screen-reader-text\">  JEM-2100plus: Specimen Stage Shift and Tilt<\/span><\/a><\/p>\n","protected":false},"author":11,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_locale":"en_US","_original_post":"https:\/\/www.aem.imr.tohoku.ac.jp\/?p=3200","footnotes":"","jetpack_post_was_ever_published":false},"categories":[1],"tags":[],"class_list":["post-5461","post","type-post","status-publish","format-standard","hentry","category-uncategorized","en-US"],"jetpack_featured_media_url":"","_links":{"self":[{"href":"https:\/\/www.aem.imr.tohoku.ac.jp\/wp-json\/wp\/v2\/posts\/5461","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.aem.imr.tohoku.ac.jp\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.aem.imr.tohoku.ac.jp\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.aem.imr.tohoku.ac.jp\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/www.aem.imr.tohoku.ac.jp\/wp-json\/wp\/v2\/comments?post=5461"}],"version-history":[{"count":4,"href":"https:\/\/www.aem.imr.tohoku.ac.jp\/wp-json\/wp\/v2\/posts\/5461\/revisions"}],"predecessor-version":[{"id":5762,"href":"https:\/\/www.aem.imr.tohoku.ac.jp\/wp-json\/wp\/v2\/posts\/5461\/revisions\/5762"}],"wp:attachment":[{"href":"https:\/\/www.aem.imr.tohoku.ac.jp\/wp-json\/wp\/v2\/media?parent=5461"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.aem.imr.tohoku.ac.jp\/wp-json\/wp\/v2\/categories?post=5461"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.aem.imr.tohoku.ac.jp\/wp-json\/wp\/v2\/tags?post=5461"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}